Dear Arne,

> I presume the units on the y-axis are a scaled 'magnitude'.

   The y-axis represents the flux relative to the comparison star.
(The scale is linear).

>   Another technique that I have not seen, is to stack
> images at equal phase and then extract.  I bet you will
> get better S/N than is shown in your plot.

   The main difficulties may be different orientations of images.  One
must interpolate something (though I have done before), which may introduce
some uncertainty.  In the present method of PSF-based extraction, we
don't have to care about the individual image orientation, and only
have to treat with relative counts.

Regards,
Taichi Kato